Charging machine
The portable charger produced by the company uses high-frequency switching power technology, small size, light weight, high efficiency; Combined with intelligent charging technology, to prolong the battery life and timely battery full charge for the purpose of over coming The disadvantages of the power frequency charger design, and the power frequency charger can significantly extend the battery life, so that it is completely free Manual duty automatic charging working state, with battery charging, battery overdischarge protection function, charging current can be adjusted, Especially suitable for unattended charging occasions. With output overvoltage, overcurrent, short circuit protection; The whole machine overheating protection function. Suitable for electric vehicle, electric power screen, program control Switch, radio and television transmitter, communication machine station, AGV car, battery charging, power supply system, etc. (desktop or vehicle-mounted)48V40A AGV Automatic charging pile
wokring temperature:-15°C ~+50°C Storage temperature:-40°C ~+85°C Safety standard:comfort to EN60950 Product specification Number | Parameter category | Parameter name | Description |
1 | Ac output | Input mode | Single-phase three-wire system |
2 | Input voltage | Ac voltage:2 20 VAC,Fluctuation range:180VAC ~ 260 VAC | |
3 | Input frequency | Rated frequency:50 Hz,Fluctuation range:45 Hz~65 Hz | |
4 | Input current | 15A | |
5 | Surge current | ≤10 A | |
6 | efficiency | ≥91% | |
7 | Input power factor | 0.95 | |
8 | do output | Output power | Rated output:2400W max |
9 | 20A Output voltage | Rated output:40-60VDC,58.4V | |
10 | Current limiting value | seeting:5-40A,20A peak current:40A | |
11 | Voltage stabilization accuracy | ≤±0.6% | |
12 | Stopping current | 0.3A,can setting | |
13 | Broadband noise voltage | ≤50mV (3.4kHz~150kHz) ≤20mV (0.15MHz~30MHz) | |
14 | Safety protection | Insulation strength | input-output:2 000 VAC Input to the case:1 500 VAC output to the case:500 VAC |
15 | Leakage current | ≤20 mA | |
16 | Safety standard | conform to EN60950 | |
17 | Compression distance | 35mm | |
18 | reliability | average failure of Interval time MTBF≥100 000 h | |
19 | Cooling mode | Forced air cooling mode (automatic charger has DC fan inside, air flux is 20 CFM) | |
20 | Working environment | working temperature | ·-15℃~50℃ |
21 | Storage temperature | ·-40℃~85℃ | |
22 | Relative humidity | ·10%~90%(No Condensation) | |
23 | CAN communication, our company supply standard charging or customized protocol according to customer requiarements | ||
24 |
Main characteristics
(1) Unique portable integrated chassis design; (2) Modular design, can be applicable to different AGV scheme requirements; (3) It can receive instructions from upper computer to realize automatic charging of AGV; (4) short circuit, over voltage, over current, over temperature, reverse protection, etc. (5) programmable charging current and voltage;48V20A AGV Automatic charging pile
working temperature:-15°C ~+50°C Storage temperature:-40°C~+85°C Safety standard:comfort to EN60950 Product specification Number | Parameter category | Parameter name | Description |
1 | Ac output | Input mode | Single-phase three-wire system |
2 | Input voltage | Ac voltage:2 20 VAC,Fluctuation range:180VAC ~ 260 VAC | |
3 | Input frequency | Rated frequency:50 Hz,Fluctuation range:45 Hz~65 Hz | |
4 | Input current | ≤6A | |
5 | Surge current | ≤10 A | |
6 | efficiency | ≥91% | |
7 | Input power factor | 0.99 | |
8 | Do output | Output power | Rated output:1200W max |
9 | 20A Output voltage | Rated output:54.7V | |
10 | Current limiting value | 20A | |
11 | Voltage stabilization accuracy | ≤±0.6% | |
12 | Stopping current | 1A | |
13 | The telephone weighs heavy noise | ≤2 mV | |
14 | Safety protection | Insulation strength | input-output:2 000 VAC Input to the case:1 500 VAC output to the case:500 VAC |
15 | Leakage current | ≤20 mA | |
16 | Safety standard | standard EN60950 | |
17 | Compression distance | 35mm | |
18 | reliability | average failure of Interval time MTBF≥100 000 h | |
19 | Cooling mode | Forced air cooling mode (automatic charger has DC fan inside, air flux is 20 CFM) | |
20 | Working environment | working temperature | ·-15℃~50℃ |
21 | Storage temperature | ·-40℃~85℃ | |
22 | Relative humidity | ·10%~90%(No Condensation) | |
23 | The charging machine is connected with a brush block to realize automatic charging. When the AGV car needs to be charged, it will be parked on the brush plate. The charger will detect the battery voltage and approach the switch to work, so that it can complete automatic charging. | ||
24 |